A-5
ORDER INFORMATION
(1) Base Model 475 includes Field Communicator unit with color LCD display, System Card,
Leadset with connectors, Carrying Case, Getting Started Guide, 475 Resource CD, stylus
and straps.
(2) This option requires that the Easy Upgrade option (code U) is specified.
(3) To obtain an Australian Power Cord, order part number 00375-0003-0003.
(4) This option should only be considered if the user already has a 375 or 475 Power
Supply/Charger. If it is a 375 Power Supply/Charger, it must be the Li-Ion/NiMH version.
(5) The Easy Upgrade feature allows the user to add new System Application software and
device descriptions (DDs) to the 475 for a period of 3 years. To upgrade without this
feature, the System Card would have to be sent to a Service Center.
(6) The Graphics Option enables a user to access enhanced graphical features when using
the HART or FOUNDATION fieldbus application.
(7) Device Configuration Management provides the capability to store up to 1000
configurations and print them using the Easy Upgrade Utility.
(8) Bluetooth enables communication to a PC via the Bluetooth protocol. See list of countries
with Bluetooth approval atwww.fieldcommunicator.com.
(9) A fully charged Li-Ion Power Module is capable of delivering power for 20 hours of typical
field use. If requirements exceed this specification, a spare Power Module (code A) should
be specified.
Model Product Description
475 Field Communicator (Note 1)
Code Communication Protocol
H HART
F HART and FOUNDATION fieldbus (Note 2)
Code Battery Type
P Rechargeable Li-ion Power Module
Code Power Supply/Charger
1 Power Supply/Charger Li-ion/NiMH US/UK/EU connection types
included (Note 3)
9 Not Included (Note 4)
Code Language
E English
D German (Available to ship Sept 09)
J Japanese (Available to ship in early 2010)
R Russian (Available to ship Sept 09)
Code Product Certifications
KL ATEX, FM, CSA and IECEx Intrinsically Safe
(includes FISCO as applicable)
NA No Approval
Code Easy Upgrade
U Easy Upgrade Option (3 year) (Note 5)
9 Not Included
Code Included Options
GM Graphics (Included at no charge) (Note 6)
GM Device Configuration Management (Included at no charge)
(Note 7)
Code Bluetooth
T Bluetooth Communications (Note 8)
9 No Bluetooth Communication
Code Options
Spare Battery
A Spare Rechargeable Li-ion Power Module (Note 9)
Enclosures
S Protective Rubber Boot with Stand (Boot available to ship Oct 09)
Typical HART Model Number: 475 H P 1 E KL U GMT
Typical HART/Fieldbus Model Number: 475 F P 1 E KL U GMT
A-6
SPARE PARTS LIST
(1) Can be used to support communication between the 375/475 and the Easy Upgrade
Programming Utility or AMS Device Manager (with Handheld Communicator Interface Kit).
Either IrDA or Bluetooth Communication is required to register the 375/475 or use the
Online Licensing system.
(2) The System Card (SD) Reader allows a user the ability to upgrade a System Card much
faster than they can when using IrDA or Bluetooth. Due to the file size constraints, major
upgrades require the use of a card reader.
(3) The Easy Upgrade feature allows the user to add System Application Software and device
descriptions (DDs) to the 475 for a period of 3 years. To upgrade without this feature, the
System Card would have to be sent to a Service Center (fee would apply).
(4) These parts support license upgrades of System Cards in the field through the use of the
Field Communicator Online Licensing system. The capability is available to end users and
may also be performed by an agent on the user’s behalf. It is at the agent’s discretion if an
additional fee should apply. Any order must be accompanied by the System Card S/N.
Instant notification of when the licenses are available for download are sent to emails
provided at time of order. For further details, see the Online Licensing procedure at
www.fieldcommunicator.com.
(5) The ReNew option is available on System Cards where the Easy Upgrade license has
been expired for less than 90 days. Date of expiration can be obtained by interfacing the
475 with v3.0 (or higher) of the Easy Upgrade Programming Utility.
(6)Requires AMS Device Manager (version 6.2 or higher). Both AMS Device Manager and the
Handheld Communicator Interface kit are available for sale through select channels only.
Seewww.assetweb.comfor further details.
Description Part Number
Ruggedized 250 Ohm Load Resistor 00275-0096-0001
Rechargeable Li-Ion Power Module 00475-0002-0022
Power Supply/Charger (Li-Ion/NiMH) US/UK/EU connection types
included
00475-0003-0022
Power Supply/Charger Standard cord set (US/UK/EU cords) 00375-0003-0002
Australian (AU cord) for Power Supply/Charger 00375-0003-0003
Lead Set with connectors 00375-0004-0001
Hand Strap (pack of 2) 00475-0005-0002
Carrying Case (with spare Hand Strap and Stylus) 00475-0005-0003
Magnetic Hanger (Magnetic Hanger available to ship Sept 09) 00475-0005-0004
Protective Rubber Boot with stand (Boot available to ship Oct 09) 00475-0005-0005
Stylus (pack of 2) 00475-0006-0001
IrDA to USB Adapter (Note 1) 00375-0015-0002
System Card (SD) Reader (with USB interface) (Note 2) 00375-0018-0022
Bluetooth Adapter (Note 1) 00475-0018-0023
Stand 00475-0044-0001
Getting Started Guide 00475-0045-3001
Resource CD 00475-0049-0001
Online Licensing (Note 4)
FOUNDATION fieldbus license via Web 00375-0142-0002
Easy Upgrade (New) license via Web (Note 3) 00375-0142-0003
Easy Upgrade (Renew) license via Web (Notes 3 and 5) 00375-0142-2003
AMS Device Manager Handheld Interface Kit (Note 6)
AMS Suite: Intelligent Device Manager
Field Communicator Interface Kit (25 tags)
AW7005HC00025
AMS Suite:Intelligent Device Manager
Field Communicator Interface Kit (100 tags and above)
AW7005HC20000