伟思富奇环境试验仪器(太仓)有限公司--华南销售
主营产品:
2023年12月09日 08:52
型号 |
VT3-7012 S2 |
工作室尺寸 |
470(W)*650(D)*410(H)() |
温度范围 |
+50 °C to +220 °C() |
测量范围 |
-80 °C to +70 °C |
加工定制 |
是 |
重量 |
1000() |
品牌/型号 |
富奇/VT3-7012 S2 |
材质 |
SUS304不锈钢 |
低温室升温速率 |
2 K/min【ording to IEC 60068-3-5】 |
低温室降温速率 |
6 K/min【ording to IEC 60068-3-5】 |
高温室升温速率 |
14 K/min【ording to IEC 60068-3-5】 |
Vötsch Temperature Shock Test Cabinet
VT³ 7012 S2
Test space volume approx. 120 litres
Temperature range
of the hot chamber +50 °C to +220 °C
Temperature range
of the cold chamber -80 °C to +70 °C
Standard featuresPowder coated housing made of galvanised steel sheetWindow, 355 mm x 355 mm, in the hot chamber1 Ultra-lightweight shelf(mesh width 8 mm)incl. railsCradle in loading position lockedMax. loading capacity of cradle 50 kg1 leadthrough 80 mm ØVolume compensation system for long-term operationWater-cooled refrigeration unitCFC-free refrigeration unitComfortable 8” colour-touchpanelCONTROLPADfor door with status indicationHighly efficient 32 bit control and monitoring systemSIMPACInterfaces USB and ethernetDigital I/O, potential-free 24 V, 4 freely disposable inputs/outputsIndependent adjustable temperature limiter tmin/ tmax in cradle
for hot and cold zonePotential free contact for switching-off of test specimensAdjustable software temperature limiter tmin/ tmax Status displayCycle couter, total no. of cycles / remaining run timeOperating hour counterTemperature control using movable sensor in cradle or alternatively
fixed sensor in hot or cold zoneDefrosting cycles automatic and programmableDwell time start programmableAlready programmed and may be called up at any time:
MIL-STD- 883 F, method 1010.8 Intensity of test A,B,C,D,FCalibration of 2 temperature values1 Operating instructionCommissioning and test run in our companyPerformance data
Temperature tests
Temperature range
of the hot chamber +50 °C to +220 °C
Temperature range
of the cold chamber -80 °C to +70 °C
Hot or cold chamber may also be utilized as inpidual temperature chamber.
Temperature deviation
in time
in centre of working space ±0.3 K to ±1.0 K
Test space with test specimenTemperature homogeneity
in space relative to the
set value[1] ±0.5 K to ±2.0 K
Heating rate of hot chamber
according to IEC 60068-3-5 14K/min.
Cooling rate of cold chamber
according to IEC 60068-3-5 6.3K/min.
Heating rate of cold chamber
according to IEC 60068-3-5 2.0K/min.
Temperature changing tests:
MIL-STD- 883 F, method 1010.8,
Severity D with 12 kg of IC’s
distributed over 3 shelves;
measurement on test speci-
mens Adaption time <15 min.
The following standards are
met DIN 40046, page 14, test Na, transfer time
<10 sec.; IEC-60068-2-14, test Na²,
transfer time <10 sec.;
MIL-STD-810 E, method 503;
MIL-STD- 883 F, method 1010.8
variants A,B,C,D,F
JEDEC standard JESD22-A101-A
Temperature calibration
values are measured at -40 °C cold chamber
+125 °C hot chamber
Dimensions and weights
Dimensions test space 470 mm wide
650 mm deep
410 mm high
Test space capacity approx. 120 l
Dimensions cabinet 970 mm wide(without colour touchpanel)
(Transport dimensions) 2350 mm deep(without colour touchpanel)
2450 mm high(with cover for ball spindle)
Minimal transport 970 mm wide
dimensions[1] 2190 mm deep
1985 mm high
Assembly complements it’s only possible about the warm chamber. The door of the cold chamber is locked mechanical.Weight approx. 1000 kg net
Technical data
Operating conditions ambient temperature: +10 °C to +35 °C;
max. rel. air humidity 75 % r. h.;
max. dew point +20 °C
Installation conditions Please protect test chamber against direct
sunlight and sources of heat.
Heat dissipation to
installation space max. approx. 0.8 kW
Sound pressure level approx. 56 dB(A) measured in 1 m
distance from the front and in 1.6 m
height at free field measurement according
to EN ISO 11201.
Drain for condensate and
cleaning water hose connecting sleeve Ø 12 mm
Electrical:
Nominal voltage 3/N/PE AC 400V±10% 50Hz
Nominal power approx. 10 kW
Nominal current approx. 25 A (neutral conductor fully loaded)
Connector CEE 32 A
Connection cable approx. 3.5 m
Fuse protection provided
by the customer 32 A gG, customer provided
Protection class electrical compartment: IP 54
control unit: IP 54
Energy consumption approx. 200 kWh / 24h
(in standard operation) With tests in accordance with MIL-STD- 883 F
method 1010.8, severity Bwith 12 kg test
specimen, dwelling time: 30 min.
Cooling water:
Cooling water connection water inlet R 3/4” female thread
water outlet R 3/4” female thread
Heat dissipation to
cooling water max. approx. 15kW
Cooling water consumption max. 1.3 m³/h at ?t = 10 K
max. 2.6 m³/h at ?t = 5 K
With tests in accordance with MIL-STD- 883 F,
method 1010.8
Cooling water quality without contaminant (max. grain size:
100 Micrometers, pH-value approx. 7),
water pressure: 2.5 to 6 bar,
differential pressure>2 bar,
water temperature: +12 °C to max. +28 °C
For operation with well/pond water special
measures must be taken, on request.
联系方式