DNP Standard color Viewer The DNP Standard color Viewer is a light source whichenables you to evaluate and adjust video and still cameras. Withits high-frequency Fluorescent lighting method, it handles imageswithout flicker. Specification Light source: DNP Standard color Viewer lamp
(Four 10W dedicated fluorescent tubes are used) Power supply: AC100V 50, 60Hz Lighting method: High Frequency lighting method 20KHz Color rendering: Over 90% rendering evaluation-point for each color Color temperature: (Measured by Minolta CL-200) Operating temperature: 10~40℃ Operating humidity: Below 80%(avoid dew) Major diameter dimension: 375W×365H×165D m/m Luminance plane dimension: 250W×190H m/m Color chart dimension: 320W×290H m/m Power consumption: 80W Weight: 6.5kg/7.5kg CCV-31F
CCV-51F CCV-31F/G
CCV-51F/G ●The Luminance plane characteristics: according to the typesof self-contained fluorescent lamp Product Type Luminance Color Temperature Lamp Color Temperature Luminance Color matching shift Weight CCV-31F Fixed FL10WW-DLB 3100K±300 Over 1300cd/m2 Within 10% 6.5kg CCV-51F Fixed FL10D-EDL-56K 5100K±300 Over 1400cd/m2 Within 10% 6.5kg CCV-31F/G Volume adjustable FL-10WW-DLB 3100K±300 Over 850~1300cd/m2 Within 10% 7.5kg CCV-51F/G Volume adjustable FL10D-EDL-56K 5100K±300 Over 850~1400cd/m2 Within 10% 7.5kg *The colortemperature if Luminance. Color Temperature Conversion Type viewerranges over 50k according to the change of the Luminance.
*The specification may change without notice Operation Manual 【1】 Before using theproduct: Power supply AC 100V, 50/60Hz shared Light source 10W DNP Standard color Viewer Lamp (4) Power consumption 80W 【2】 Using the DNPStandard color Viewer (1) Plug the power cable of the product into AC100V 【Precautions】 Do not connectany power supply other than AC100V
If the other power supply connected by accident, the inverterinside will burned out (2) Turn on the power switch (3) Lamp lights: the lamp light will stabilised after 15 to 20minutes at the room temperature(20℃) (4) If the lamp does not lit, call for Service Office for theconfirmation as described on other documents. (5) To suspend snaking of the lamp, press power switch 3 to 4 times[as ON/OFF]. 【3】 If the light doesnot lit Call for Service Office to confirm thefollowing: (1) AC 100V supplied to the wall socket. (2) Plug the product into the wall socket. (3) Turn the power supply switch of the product ON Still the lamp does not lit: Consider thefollowing: (1) Two of the viewer lamps lit simultaneously, one of the fuses ofthe inverters has blowouts. (2) Four of the viewer lamps does not light means that each of thefuses of the two inverters has blowouts. 【Precautions】 The aboveoccurs if the applied power supply is not AC 100V.
Fuse bum out cause internal burnout of inverter. The burnedinverter needs to replace. 【4】 How to replace thelamp and keep it clean Place the Viewer on the flat table, and plug outthe power supply cable from the wall socket.
Remove the used device in the following order: (1) Unfasten the two of grub screws on the top frame. (2) To remove the top frame from the main unit;
Holding 50 to 60 mm the grub screw of the top frame and press itforward. (3) Remove the glass plate and acrylic plate. 【Precaution】 Glass plateeasily breaks and may hurt your hands and fingers.
Handle the edge of the plate with care not to scratch. ◆Replacing the lamps: (1) When the lamps used over 2,000 hours or one year, it needs toreplace. (2) Remove the Lamp Tubes: Hold the edge of the Lamp Tubes, andturn it 90 degree. ◆Cleaning the device: (1) Impregnate alcohol to gauze then apply it onto the surface ofthe reflection plate / acrylic plate / glass surface to remove thedirt. (2) Clean the device once in six months to one year to keep qualityof the Color Temperature and Luminance. 【5】 OtherPrecautions Handling the viewer needs the following precautionsbecause it contains the parts using glass. (1) Do not add strong impact on the viewer (2) Do not put any heavy items on the surface of the viewer DNP Standard Color Viewer for HDTV The DNP Standard color Viewer for HDTV is a light sourcewhich enables you to evaluate and adjust video and still cameras.With its high-frequency Fluorescent lighting method, it handlesimages without flicker. Specification Light source: DNP Standard color Viewer lamp
(Four 15W dedicated fluorescent tubes are used) Power supply: AC100V 50、60Hz Lighting method: High Frequency lighting method 20KHz Color rendering: Over 90% rendering evaluation-point for each color Color temperature: (Measured by Minolta CL-200) Operating temperature: 10~40℃ Operating humidity: Below 80%(avoid dew) Major diameter dimension: 490W×380H×150D m/m Luminance plane dimension: 272W×153H m/m Color chart dimension: 310W×200H m/m Power consumption: 110W Weight: 10kg HDF-51F The characteristics according to the Viewer Luminanceplane Product Type Lamp Color Temperature Luminance Color matching shift HDF-51F FL15D-EDL-56K 5100K±300 Over 3500cd/m2 Within 5% *Thespecification may change without notice Operation Manual 【1】 Before using theproduct: Power supply AC 100V, 50/60Hz shared Light source 15W DNP Standard color Viewer Lamp (4) Power consumption 110W 【2】 Using the DNPStandard Color Viewer for HDTV (1) Plug the power cable of the product into AC100V 【Precautions】 Do not connectany power supply other than AC100V
If the other power supply connected by accident, the inverterinside will burned out (2) Turn on the power switch (3) Lamp lights: the lamp light will stabilised after 15 to 20minutes at the room temperature(20℃) (4) If the lamp does not lit, call for Service Office for theconfirmation as described on other documents. (5) To suspend snaking of the lamp, press power switch 3 to 4 times[as ON/OFF]. 【3】 If the light doesnot lit Call for Service Office to confirm thefollowing: (1) AC 100V supplied to the wall socket. (2) Plug the product into the wall socket. (3) Turn the power supply switch of the product ON Still the lamp does not lit: Consider thefollowing: (1) Two of the viewer lamps lit simultaneously, one of the fuses ofthe inverters has blowouts. (2) Four of the viewer lamps does not light means that each of thefuses of the two inverters has blowouts. 【Precautions】 The aboveoccurs if the applied power supply is not AC 100V.
Fuse bum out cause internal burnout of inverter. The burnedinverter needs to replace. 【4】 How to replace thelamp and keep it clean Place the Viewer on the flat table, and plug outthe power supply cable from the wall socket.
Remove the used device in the following order: (1) Unfasten the four of grub screws on the top frame. (2) Pull up the upper frame. (3) Remove he glass plate and acrylic plate. 【Precautions】 Glass plateeasily breaks and may hurt your hands and fingers.
Handle the edge of the plate with care not to scratch. ◆Replacing the lamps: (1) When the lamps used over 2,000 hours or one year, it needs toreplace. (2) The socket of the lamp has a spring inside, press it towardone-way. ◆Cleaning the device: (1) Impregnate alcohol to gauze then apply it onto the surface ofthe reflection plate / acrylic plate / glass surface to remove thedirt. (2) Clean the device once in six months to one year to keep qualityof the Color Temperature and Luminance. 【5】 OtherPrecautions Handling the viewer needs the following precautionsbecause it contains the parts using glass. (1) Do not add strong impact on the viewer (2) Do not put any heavy items on the surface of the viewer