【Function Instructions】
For icons of function instructions, please refer to names and icons of parts.
① Container of liquid tested
② Testing salt concentration
③ Displaying salt concentration:0%~0.7%(appropriate);0.7%~1.1%(strong);1.1%~2.0%(very strong)。
⑤ ON/OFF button, used to test after pressing the button and supplying power.
【Operating Instructions】
n Inspect whether the salt tester probe is clean. If not, please wipe it with clear water, and fix the moveable soup ladle.
n After pressing the salt tester ON/OFF switch, observe the LCD sheet. LO indicates the battery has low voltage and shall be replaced.
n Put the tested solution into the moveable soup ladle, with the salt tester probe at least below the solution.
n Press the salt tester ON/OFF switch to conduct the testing, with the inspection value shown on the LCD after 5 seconds.
n After the test, remove the moveable soup ladle, and clean the tester probe with clear water.
【Performance and Specification】
Object tested:Aqueous solution (food/water, etc.)
Measuring range:0%~2.0%
Measuring accuracy:±0.15% (0.0%~0.7%)
Applicable temperature range: 20℃~80℃
Power input:4×1.5=6V LR44×4
Working current:MAX 20mA
Dimensions:270×34×20 (mm)
Weight:Approx. 65 g
Calculation formula:salt content = total mass×concentration
Example:One cup of solution has the mass of 150g, with the concentration of 0.5%
150g×0. 5%= 0.75g'