欢迎来到全天候!
注册
全天候首页
发布产品

长沙力高捷创仪器有限公司

主营产品:

18665876229
全天候> 仪器仪表> 电子测量仪器> 其他电子测量仪器> 供应日本岩崎 SC-7217 通用频率计数器

供应日本岩崎 SC-7217 通用频率计数器

2023年09月10日 08:08

  • 价格 面议 (起订量: 1件 | 可售数量:面议)
  • 店铺地址 湖南长沙中国 湖南 长沙 长沙市雨花区 中意一路66号亚商大厦A栋2524室
立即咨询
查看联系方式
详情描述
型号
SC-7217 SC-7215 SC-7207H SC-7206H SC-7205H
测量范围
0.6mHz to 230MHz
用途
频率计

日本岩崎 SC-7217 SC-7215 SC-7207H SC-7206H SC-7205H 通用频率计数器

一、产品特点 Easy operation with one key, one action Easy-to-read fluorescent Display provides detailed information display of 5x7 dots. * Full-spelling display guide strongly supports operation Auto trigger function eliminates trigger level settings. Trigger level also can be set manually. Comparator and statistical calculation functions easily make "In-line" operations more efficient. Capable of unit conversion (rpm, speed, etc.) by using the scaling calculation function. Waveform amplitude measurement at peak voltage for input signal can be checked easily. Save/recall function of panel setup helps In-line application more efficient. Full remote control via standard equipped GP-IB (option SC-701 for SC-7205H) or RS-232 interfaces. * 200 data/sec high-speed real-time data transfer contributes to the improvement of line throughput. Option provide wide expandability Comparator output via digital I/O (SC-702). External trigger input. * 150mA, 50V output sufficient to be used in line monitoring equipment as is. Measuring function (selection guide) * SC-7206H is not equipped with EXT-B gate Measuring functions Gate Model Internal EXT-B MANUAL SGL SC-7207H SC-7206H SC-7205H FREQ-A (Frequency) Selectable Disabled FREQ-B (Frequency) FREQ-LINE (Frequency) Disabled for 1ms and 10ms FREQ-C (Frequency) PERI-A (Period) DUTY-A (Duty cycle) P.W-A (Pulse width) TOT-A (Totalize) T.INT A-B (Time interval) FREQ A/B (Frequency ratio) PHAS A-B (Phase) Peak voltage A - - - - Peak voltage B - - - - :Selectable :Disabled :Disabled for 1ms and 10ms 二、详细参数 Frequency A (FREQ-A) •Measuring range and resolution * SC-7206H is not equipped with EXT-B gate

SC-7207H SC-7206H, SC-7205H Reference time

(reference frequency) 10ns (100MHz) 100ns (10MHz) Range DC 6mHz to 230MHz 0.6mHz to 230MHz AC 10Hz to 230MHz Resolution and count method Frequency Below 100MHz 100MHz or more Below 10MHz 10MHz or more Count method Reciprocal count Direct count Reciprocal count Direct count 1ms gate 5 digits 1kHz 4 digits 1kHz 10ms gate 6 digits 100Hz 5 digits 100Hz 0.1s gate 7 digits 10Hz 6 digits 10Hz 1s gate 8 digits 1Hz 7 digits 1Hz 10s gate 9 digits 0.1Hz 8 digits 0.1Hz EXT-B gate * Reciprocal count method: The number of digits is determined by external gate time SGL gate Reciprocal count method: The number of digits is determined by measured signal >> Frequency Measurement Error in Universal Counters AC Line Frequency (FREQ-LINE) (for SC-7207H and SC-7205H only) •Measuring range and resolution

SC-7207H SC-7205H Reference time 10ns 100ns Range 45Hz to 440Hz Resolution 0.1s gate 7 digits 6 digits 1s gate 8 digits 7 digits 10s gate 9 digits 8 digits Frequency C (FREQ-C) (for SC-7207H and SC-7206H only) •Measuring range and resolution

SC-7207H SC-7206H Reference time

(reference frequency)

10ns (100MHz) 100ns (10MHz) Range

(for AC coupling only)

100MHz to 3GHz

1/16 prescaler 100MHz to 2GHz

1/16 prescaler Resolution and count method Measured signal Below 1.6GHz 1.6GHz or more Below 160MHz 160MHz or more Count method Reciprocal count Direct count Reciprocal count Direct count 1ms gate 5 digits 10kHz 4 digits 10kHz 10ms gate 6 digits 1kHz 5 digits 1kHz 0.1s gate 7 digits 100Hz 6 digits 100Hz 1s gate 8 digits 10Hz 7 digits 10Hz 10s gate 9 digits 1Hz 8 digits 1Hz EXT-B gate Reciprocal count method: The number of digits is determined by external gate time Not equipped with EXT-B Period A (PERI-A) •Measuring range and resolution *SC-7206H is not equipped with EXT-B gate

SC-7207H SC-7206H, SC-7205H Reference time 10ns 100ns Range DC couple 5ns to 171s 5ns to 1,717s AC couple 5ns to 0.1s Resolution

1ms gate 5 digits 4 digits 10ms gate 6 digits 5 digits 0.1s gate 7 digits 6 digits 1s gate 8 digits 7 digits 10s gate 9 digits 8 digits EXT-B gate * The number of digits is determined by external gate time SGL gate The number of digits is determined by measured signal Duty ratio A (DUTY-A) •Measuring range and resolution

SC-7207H SC-7206H, SC-7205H Input signal frequency range Same as FREQ-A Measuring range SGL gate 0.01µ to 99.999,999,99 [%] Internal gate 0.2µ to 99.999,999,8 [%] 2µ to 99.999,998 [%] Measuring resolution SGL gate 10ns/input period

x 100 [%] 100ns/input period

x 100 [%] Average count of internal gate 1 to 24 10ns/average input period

x 100 [%] 100ns/average input period

x 100 [%] 25 to 2,499 1ns/average input period

x 100 [%] 10ns/average input period

x 100 [%] 2,500 to 249,999 100ps/average input period

x 100 [%] 1ns/average input period

x 100 [%] 250,000 to 24,999,999 10ps/average input period

x 100 [%] 100ps/average input period

x 100 [%] 25,000,000 or more 1ps/average input period

x 100 [%] 10ps/average input period

x 100 [%] Pulse width A (P.W-A) •Minimum pulse width: 6ns

•Maximum repetitive frequency: 80MHz

•Measuring range and resolution

SC-7207H SC-7206H, SC-7205H Reference time 10ns 100ns Measuring range SGL gate 10ns to 171s 100ns to 1,717s Internal gate (1ms to 10s) 10ns to approx. 1/2 gate time 100ns to approx. 1/2 gate time Measuring resolution SGL gate 10ns to 100ns 100ns to 1ms Average count of internal gate 1 to 24 10ns 100ns 25 to 2,499 1ns 10ns 2,500 to 249,999 100ps 1ns 250,000 to 24,999,999 10ps 100ps 25,000,000 or more 1ps 10ps Time interval A --> B (T.INT A --> B) (for SC-7207H and SC-7205H only) •Minimum time interval: 6ns

•Maximum repetitive frequency: 80MHz

•Measuring range and resolution

SC-7207H SC-7205H Reference time 10ns 100ns Measuring range SGL gate 10ns to 10,955s 100ns to 109,951s Internal gate (1ms to 10s) 10ns to approx. 1/2 gate time 100ns to approx. 1/2 gate time Measuring resolution SGL gate 10ns to 10µs 100ns to 100µs Average count of internal gate 1 to 24 10ns 100ns 25 to 2,499 1ns 10ns 2,500 to 249,999 100ps 1ns 250,000 to 24,999,999 10ps 100ps 25,000,000 or more 1ps 10ps Frequency ratio A/B (FREQ A/B) (for SC-7207H and SC-7205H only) •Measuring range and resolution

SC-7207H SC-7205H Input signal frequency range Both CH-A and CH-B are the same as that for FREQ-A Measuring range Internal gate (1ms to 10s) 1E-9 to 1E+9 Measuring resolution Internal gate (1ms to 10s) 1+LOG (CH-A input frequency x gate time) digits Phase measuring A --> B (PHAS A --> B) (for SC-7207H and SC-7205H only) •Minimum time interval: 6ns

•Maximum repetitive frequency: 80MHz

•Measuring range and resolution

SC-7207H SC-7205H Reference time 10ns 100ns Measuring range SGL gate 0.1µ to 359.999,999,9 [°] Internal gate 1µ to 359.999,999 [°] 10µ to 359.999,99 [°] Measuring resolution SGL gate 0ns/input period

x 360 [°] 100ns/input period

x 360 [°] Average count of internal gate 1 to 24 10ns/average input period

x 360 [°] 100ns/average input period

x 360 [°] 25 to 2,499 1ns/average input period

x 360 [°] 10ns/average input period

x 360 [°] 2,500 to 249,999 100ps/average input period

x 360 [°] 1ns/average input period

x 360 [°] 250,000 to 24,999,999 10ps/average input period

x 360 [°] 100ps/average input period

x 360 [°] 25,000,000 or more 1ps/average input period

x 360 [°] 10ps/average input period

x 360 [°] Accumulation measuring (TOT-A) Minimum pulse width 2.5ns Input frequency range Same as that for FREQ-A Measuring range 0 to 4,294,967,295 counts when scaling calculation is set to off Measuring error ±1 [count] (only when gate opens/closes) Peak voltage measuring (SC-7206H is not equipped with CH-B) Measures and displays in real-time the voltage amplitude of the measured signal at CH-A or CH-B. Frequency range 150Hz <= input frequency <= 50MHz Response time 2 seconds or less Voltage range ±2.50V (ATT off, resolution: 10mV), ±50.0V (ATT on, resolution: 100mV) Measuring error ATT off: 10% of indication ±50mV

ATT on: not specified CH-A, CH-B input terminal (SC-7206H is not equipped with CH-B) Input RC Approx. 1MW/20pF or less Coupling AC or DC Low pass filter Off, 10kHz Attenuator Off, 26dB (1/20) Trigger level Measuring Range ATT

off -2.50V to +2.50V

(resolution: 10mV) ATT

on -50.0V to +50.0V

(resolution: 100mV) accuracy

(0°C to +40°C) ATT

off 10% ±30mV of the set value

(±3% when +2V to -2 V ) ATT

on 10% ±300mV of the set value

(±3% when +40V to -40 V ) Operating input voltage range ATT off ±2.5V ATT on ±50V Input sensitivity Manual trigger ATT

off 30mVrms (DC to 230MHz) ATT

on 0.6Vrms (DC to 230MHz) Auto trigger ATT

off 200mVrms

(10kHz to 230MHz, sine wave) ATT

on 4Vrms

(10kHz to 230MHz, sine wave) CH-C input terminal (for SC-7207H and SC-7206H only) Maximum input power +30dBm (approx. 7Vrms when 1mW/50W = 0dBm as a reference) Impedance Approx. 50W Coupling AC VSWR 2.0 or less (SC-7207H: 100MHz to 3GHz, SC-7206H: 100MHz to 2GHz) Input sensitivity (Sine wave: up to 2 GHz for SC-7206H) AGC off/on -20dBm (100MHz <= input frequency <= 300MHz) -25dBm (300MHz < input frequency <= 1.5GHz) -20dBm (1.5GHz < input frequency <= 3.0GHz) Burst detection Detection frequency range SC-7207H 100MHz to 3GHz SC-7206H 100MHz to 2GHz Input sensitivity (sine wave: up to 2GHz for SC-7206H) AGC

off -20dBm (100MHz <= input frequency <= 1.2GHz) -10dBm (1.2GHz < input frequency <= 3.0GHz) Detection delay time 500µs

(Burst period >= set gate + 500µs) 10MHz STD IN BNC terminal for more stable input of the external reference frequency Frequency 10MHz±50Hz (±5ppm) Amplitude 1Vrms to 5Vrms, threshold = 0V Input resistance Approx. 6.4kW Input coupling AC 10MHz STD OUT/(MARKER OUT) BNC terminal for output of internal reference oscillator or marker signal.

Marker signal is a signal that presupposes the brightness modulation (Z axis) of the analog oscilloscope. It is enabled at the SGL gate when the function is in between the time interval (T.INT A --> B) and phase (PHAS A --> B). Output is "Lo level" from the start of CH-A measuring to the start of CH-B measuring. Output CMOS level Reference frequency output 10MHz: Stability is the same as that for the internal reference oscillator. Marker output In the 5MHz band, L is output during actual measuring.

(for SC-7207H and SC-7205H only. Marker selection is disabled with SC-7206H.) Output interface •RS-232 is equipped as standard

•GP-IB is equipped as standard (option SC-701 for SC-7205H)

•Digital I/O option can be installed (SC-702) Environmental conditions •Warm-up time: 60 minutes or more

•Operating temperature/humidity: 0°C to +40°C/85%R.H or less (no condensation)

•Storage temperature/humidity: -20°C to +60°C/90%R.H or less (no condensation) Reference oscillator Equipped with SC-7207H, SC-7206H and SC-7205H as standard

Output is possible to the 10MHz OUT BNC terminal on the rear panel of the main unit.

•Oscillation frequency: 10MHz

•Temperature characteristics: ±2.5ppm/unit environmental temperature: 0°C to +40°C

•Aging rate: ±1.0ppm/year Power supply conditions and power supply voltage changes (factory option) •Voltage: AC100V / 110V to 120V / 220V to 240V

•Frequency: 50Hz, 60Hz, 400Hz

•Power consumption: At AC100V with optional SC-701 and SC-702 are installed. SC-7207H 36VA MAX SC-7206H 33VA MAX SC-7205H 31VA MAX Size (210±2)W x (99±2)H x (353±2)L mm

(excluding options and protruded parts) Weight 4.0kg or less (including optional SC-701 and SC-702) Accessory Power cord (1), operation manual CD-ROM (including options) (1)

免责声明:该产品“供应日本岩崎 SC-7217 通用频率计数器”由用户所提供。该公司介绍、产品等相关信息均由用户自行负责,商品内容真实性、准确性、合法性由用户完全承担,全天候对此不承担任何保证责任。
联系方式
  • 公司名称长沙力高捷创仪器有限公司
  • 联系卖家吴玉进
  • 联系方式18665876229
  • 地址湖南长沙中国 湖南 长沙 长沙市雨花区 中意一路66号亚商大厦A栋2524室
企业介绍
长沙力高捷创仪器有限公司 主营产品:
所在地区:
湖南长沙中国 湖南 长沙 长沙市雨花区 中意一路66号亚商大厦A栋2524室
好货推荐
查看详情
面议
供应维修德国惠美HAMEG HMS1000 惠美频谱分析仪
长沙力高捷创仪器有限公司
湖南长沙中国 湖南 长沙 长沙市雨花区 中意一路66号亚商大厦A栋2524室
查看详情
面议
供应维修日本目黑Meguro MAK-6630 音频分析仪HD RADIO信号源
长沙力高捷创仪器有限公司
湖南长沙中国 湖南 长沙 长沙市雨花区 中意一路66号亚商大厦A栋2524室
查看详情
面议
供应维修韩国泰思康TESCOM TC-3000C 蓝牙测试仪
长沙力高捷创仪器有限公司
湖南长沙中国 湖南 长沙 长沙市雨花区 中意一路66号亚商大厦A栋2524室
返回