DESCRIPTIONS & OPERATIONS
The Footwear tester is complete personal ground test system. The Tester incorporates a unique test circuit design, which improves uracy of testing and eliminates the need for separate foot grounder test units . Blue LED and an audible alarm indicate faulty connections "Fail HI". Red LED and an audible alarm indicate low resistance or failed resistor "Fail LO". Green LED indicates proper grounding "OK". Test parameters are factory set to pass 750K-100M, but are adjustable to match your own specifications.
The unit comes equipped with a 9 volts battery. The test verifies that a continuous path between the operators , footwear and ground cord exits, with a test voltage of 9volts DC, the tester is specially designed to perform this test without harm to the operator.
When testing conductive shoes, test each foot separately to ensure proper operation and complete protection.
A. Place one foot on the plate , if the floor is conductive ,lift the foot you are not testing off of the floor during this test .
B. Press the test button so that the unit activates. Hold down for 2-3 seconds .
C. lighting of the green "PASS" LED indicates that the foot ground assemblies are functioning properly.
D. If either red "Fail LO" or blue "Fail HI" LEDS light and the audible indicator sounds, the wearer should check the foot-grounding device immediately.
E. Repeat steps A throung B with other foot .